These pumps are available in single- and dual-head styles. Airflow capabilities for the entire Gast Pump line range from 0. Hg 31 mbar , and pressure up to 60 psig 4. Electric motors are available in dual frequency, shaded pole, and permanent split capacitor psc versions, as well as AC multi-voltages for worldwide applications. Add To Cart. Enquiry sent successfully.

Author:Gumuro Fenrisida
Country:Haiti
Language:English (Spanish)
Genre:Automotive
Published (Last):18 October 2011
Pages:164
PDF File Size:18.76 Mb
ePub File Size:19.32 Mb
ISBN:590-4-12252-357-1
Downloads:21154
Price:Free* [*Free Regsitration Required]
Uploader:Tojam



These pumps are available in single- and dual-head styles. Airflow capabilities for the entire Gast Pump line range from 0. Hg 31 mbar , and pressure up to 60 psig 4. Electric motors are available in dual frequency, shaded pole, and permanent split capacitor psc versions, as well as AC multi-voltages for worldwide applications. Add To Cart. Enquiry sent successfully. Brand: Gast. Free-air capacities up to 2. Whats Included: a 6-ft 1. View Virtual Catalog - English - gy According to the chemical Compatibility Chart on the Cole Parmer website, all of these materials get an "'A" grade with ammonia.

The shipping weight is If I am only using the vacuum side, do I need to cap the pressure side? No, leave it open so the air the pump is moving has somewhere to go. Is it posible to maitaine continius a subpressure of 20mBar in a enclosure for an IP65 test of enclosure sealings.

IP65 permits limited ingress of water under conditions of spray from low pressure jets of water from any direction. It does not indicate partial submersion in water; that requires a rating of IP67 which includes submersion up to 1 meter with no leakage. Of course, there is no guarantee. Is this pump suitable for more interupted operation?.

The rating for continuous use just means that it is suitable to run for long periods of time. It will be fine for more infrequent use and usage time. Please contact our technical application specialists for additional assistance contact information can be found on the product web page. The process of working of this equipment is to pull the air from one side and to push the same from another side. But it is working abnormally. It sounds as though the check-valves are no longer working properly.

I suggest purchasing the service kit for this pump item and replacing alll of the valves, gaskets and o-rings. This will insure a good seal is achieved all around and should rectify your issue.

We currently have this pump that was purchased about 11 months ago. It has recently stopped vacuuming as well as it used to and it almost to the point of not vacuuming at all. Is there something we can do to correct this? It sounds as though the diaphragm needs to be replaced. Which is more suitable for laboratory use? The single and dual head pumps will both reach the same level of vacuum, but the dual head pump has almost twice the free air capacity. This will evacuate a chamber to the specified level of vacuum more rapidly.

More Info. Replacement neoprene diaphragm for all SKU s in th Gast AJ Pressure Regulator, 0 to psig, 2 cf Service kit for all pumps in the XX Series. Previous Next. Close Product Added To Cart! Quantity Added:. Total Including GST :. Shipping Ex. GST :. You have qualified for free shipping with this order. Continue Checkout. You May Also Need:. Close Product Enquiry. Product URL:. First Name:. Last Name:. Phone Number:. Your Enquiry:. Send Enquiry. Countries Australia New Zealand.

Height InchShort. Max Vacuum inHg. Max pressure psi. Max Temperature DegreeF. Max Vacuum torr. Noise level dB. Length InchShort. Max Temperature DegreeC. Max Vacuum mbar. Max flow rate cfm. Max Flow Rate LitersPermin. Max pressure bar. Max Vacuum mmHg. Data Sheet. Answer The shipping weight is Answer No, leave it open so the air the pump is moving has somewhere to go. Answer 20 mbar is roughly equal to 8" water column, or 0.

Answer The rating for continuous use just means that it is suitable to run for long periods of time. Answer It sounds as though the check-valves are no longer working properly. Answer It sounds as though the diaphragm needs to be replaced. Answer The single and dual head pumps will both reach the same level of vacuum, but the dual head pump has almost twice the free air capacity.

JB BOBO MODERN COIN MAGIC PDF

DOA-P504-BN

Established in the year , we, Rishab Enterprises , are a prominent Manufacturer , Supplier, Wholesaler and Retailer of a qualitative range of Chemicals and Analytical Instruments. We are indulged in serving our clients by providing them premium quality products and world class customer services to satisfy their varied requirements and demands. Since inception, we are totally committed to our mission of "efficient and reliable laboratory supplier" to provide total customer satisfaction. We have a combined marketing experience of more than 18 years in the laboratory products line, which enables us to understand the customer requirements better.